Page 2

FREEDOM OF MOVEMENT The following procedures can be used to determine if thevalve opens and closes fully. During this test the diaphragmcan be checked

Page 3

When block and tackle or a power hoist is to be used to lift the valve coverinsert a proper size eye bolt in place of the center cover plug. Pull cove

Page 4

INLETINLET1/8 NPT (THESETAPPED HOLES ARE SHOWN 90" FROM TRUE POSITION)INLETMODELS 100-02KH 100-02KHR, 100-02KHX16192176118151791810123147541311/

Page 5

1 CENTER COVER PLUG2 COVER PLUG3 STUD NUT7 PLUG, PIPE, BODY10 * GASKET "O" RING14 NAMEPLATE15 * O-RING, STEM16 RETAINER BEARING (1”-3” ONLY)

Page 6

ITEMNO.PART DESCRIPTIONCLA-VAL Copyright Cla-Val 2009 Printed in USA Specifications subject to change without notice. P.O. Box 1325 • New

Page 7

Full Open OperationWhen operating pressure below thediaphragm is greater than thepressure in the cover chamber, thevalve is held open, allowing fullfl

Page 8

Specifications4" Globe, Flanged6" Globe, Flanged6" Angle, FlangedOptionsEpoxy Coating - suffix KCAn FDA approved fusion bonded epoxycoa

Page 9

Model 100-21 Flow Chart (Based on normal flow through a wide open valve)K =894d4C2vL =K 12 fK Factor (Resistance Coefficient)The Value of K is ca

Page 10 - FREEDOM OF MOVEMENT

HKINLET OUTLET D DD JC E EE B 100-21 (Angle)B HINLET KA AA JC FF F OUTLET Dimensions100-21 (Globe)Service and InstallationCla-Val Control Valves ope

Page 11 - DISASSEMBLY

When ordering parts, please specify:• All Nameplate Data • Description • Recommended Spare Parts• Item Number • MaterialITEM DESCRIPTION1

Page 12 - 100-02 POWERTROL

This page was intentionally left blank!

Page 13 - Seat & Disc Details

24/60 Hz 115/60 Hz 120/60 Hz208/60 Hz230/60 Hz240/60 Hz440/60 Hz460/60 Hz480/60 Hz110/50 Hz220/50 Hz240/50 Hz12 VDC24 VDC28 VDC32 VDC48 VDC115 VDC1

Page 14 - PART DESCRIPTION

CLA-VAL Copyright Cla-Val 2009 Printed in USA Specifications subject to change without notice. P.O. Box 1325 • Newport Beach, CA 92659-03

Page 15 - Powertrol Valve

3/8" Flow ControlCV2.12MAXSTAMP PART NO. ONSMOOTH SURFACERESTRICTEDFLOW3/8 - 18 NPT1.84ADJUSTING STEM(TURN CLOCKWISE TOINCREASE RESTRICTION)17210

Page 16 - 6" Angle, Flanged

Limit Switch AssembliesSwitches shown inunactivated position.CLA-VAL124-02/624-02Float ValveAnnunciatorAlarmStilling WellTankSupplyDouble Pole Double

Page 17 - Functional Data Model 100-21

X105 Series Dimensions (In Inches)1. Valve Size and Basic Valve Model Number2. Catalog Number from Table Below3. All Valve Name Plate Data4. Select Si

Page 18 - Model 100-21

Limit Switch Assembly111012576843912VALVECOVER13When ordering parts,please specify:• Item Number• Description• Part NumberCollar W/Set ScrewScrew,

Page 19 - Solenoid Control

This page was intentionally left blank!

Page 20 - PL- CSM-11 (R-1/08)

CLA-VAL Copyright Cla-Val 2009 Printed in USA Specifications subject to change without notice. P.O. Box 1325 • Newport Beach, CA 92659-03

Page 21 - Flow Control

This page was intentionally left blank!

Page 22 - 3/8" Flow Control

ITEM DESCRIPTION MATERIAL1 Pipe Plug Steel2 Strainer Plug Brass3 Gasket Copper4 Screen SST5 Body Brass123453/8 NPT2.062.72SIZE STOCK NUMBER3/8 x 3/8 3

Page 24 - X105 Series Dimensions

This page was intentionally left blank!

Page 25 - Limit Switch Assembly

Cla-Val ProductIdentificationProper IdentificationFor ordering repair kits, replacement parts, or forinquiries concerning valve operation, it is impor

Page 26

HOW TO ORDERBecause of the vast number of possible configurations andcombinations available, many valves and controls are notshown in published produc

Page 27 -

Complete Replacement Diaphragm Assemblies for 100-01 and 100-20 Hytrol Main ValvesFor: Hytrol Main Valves with Ductile Iron, Bronze Trim Materials—125

Page 28

Repair Kits for 100-04/100-23 Hy-Check Main ValvesFor: Hy-Check Main Valves—125/150 Pressure Class OnlyIncludes: Diaphragm, Disc and O-Rings and full

Page 31 - How to Order

This page was intentionally left blank!

Page 33 - REPAIR KITS

This page was intentionally left blank!

Page 34 - (no bucking spring)

Principle of OperationPowertrol Valve100-02DESCRIPTIONThis manual contains information for installation, operation and main-tenance of the Cla-Val Co.